Cata-Dyne™ Heat Loss Calculation Tool
Go to Metric Version
Client Information
Project Name:
Company Name:
Contact Name:
Building Measurements
Outside Temp.:
(°F)
Length:
(ft)
Inside Temp.:
(°F)
Width:
(ft)
Air Changes/hr:
(ACH)
Height to Eaves:
(ft)
Exhaust Fan:
(CFM)
Gable Height:
(ft)
What's Gable Height?
Wind Speed:
MPH
Shielding:
None
Light
Moderate
Heavy
Very Heavy
Opening
Unit
Width
Height
Qty
Standard Material Type
U-Factor
Window 1:
ft
Single Glazed 'R'0.90 (Fixed)
Single Glazed 'R'0.90 (Moveable)
Double Glazed 5/16" air space 'R' 1.60 (fixed)
Double Glazed 5/16" air space 'R' 1.60 (moveable)
Double Glazed 1/4" air space 'R' 1.70 (fixed)
Double Glazed 1/4" air space 'R' 1.70 (moveable)
Double Glazed 1/2" air space 'R' 2.00 (fixed)
Double Glazed 1/2" air space 'R' 2.00 (moveable)
User Defined
Window 2:
ft
Single Glazed 'R'0.90 (Fixed)
Single Glazed 'R'0.90 (Moveable)
Double Glazed 5/16" air space 'R' 1.60 (fixed)
Double Glazed 5/16" air space 'R' 1.60 (moveable)
Double Glazed 1/4" air space 'R' 1.70 (fixed)
Double Glazed 1/4" air space 'R' 1.70 (moveable)
Double Glazed 1/2" air space 'R' 2.00 (fixed)
Double Glazed 1/2" air space 'R' 2.00 (moveable)
User Defined
Man Doors:
ft
Mineral Fiber Core 'R' 1.70
Urethane Foam Core with Thermal Break 'R' 2.50
Polystyrene Core with Thermal Break 'R' 2.10
User Defined
Dbl Doors:
ft
Mineral Fiber Core 'R' 1.70
Urethane Foam Core with Thermal Break 'R' 2.50
Polystyrene Core with Thermal Break 'R' 2.10
User Defined
O/H Doors:
ft
Steel Roll-up with no insulation 'R' 0.90
Steel Roll-up with insulation 'R' 4.17
User Defined
Louvre Vent:
ft
No Insulation 'R' 0.8
Insulation 'R' 1.70
User Defined
Ridge Vent:
ft
No Insulation 'R' 0.8
Insulation 'R' 1.70
User Defined
Other:
ft
Single Glazed 'R'0.90 (Fixed)
Single Glazed 'R'0.90 (Moveable)
Double Glazed 5/16" air space 'R' 1.60 (fixed)
Double Glazed 5/16" air space 'R' 1.60 (moveable)
Double Glazed 1/4" air space 'R' 1.70 (fixed)
Double Glazed 1/4" air space 'R' 1.70 (moveable)
Double Glazed 1/2" air space 'R' 2.00 (fixed)
Double Glazed 1/2" air space 'R' 2.00 (moveable)
Mineral Fiber Core 'R' 1.70
Urethane Foam Core with Thermal Break 'R' 2.50
Polystyrene Core with Thermal Break 'R' 2.10
Steel Roll-up with no insulation 'R' 0.90
Steel Roll-up with insulation 'R' 4.17
No Insulation 'R' 0.8
Insulation 'R' 1.70
User Defined
Standard Material Types:
Exterior Wall Types:
Fiberglass BATT 1" Thick 'R' 4.00
Fiberglass BATT 2" Thick 'R' 8.00
Fiberglass BATT 3" Thick 'R' 12.00
Fiberglass BATT 4" Thick 'R' 16.00
Fiberglass BATT 5" Thick 'R' 20.00
Spray on Cellulose 1" Thick 'R' 3.30
Spray on Cellulose 2" Thick 'R' 6.60
Spray on Cellulose 3" Thick 'R' 9.90
Concrete Block 8" 'R' 5.00
Concrete Slab 8" Thick 'R' 2.00
Steel Wall with no insulation 'R' 0.80
User Defined
Ceiling Types:
Fiberglass BATT 1" Thick 'R' 4.00
Fiberglass BATT 2" Thick 'R' 8.00
Fiberglass BATT 3" Thick 'R' 12.00
Fiberglass BATT 4" Thick 'R' 16.00
Fiberglass BATT 5" Thick 'R' 20.00
Fiberglass BATT 8" Thick 'R' 32.00
Spray on Cellulose 1" Thick 'R' 3.30
Spray on Cellulose 2" Thick 'R' 6.60
Spray on Cellulose 3" Thick 'R' 9.90
Translucent Ceiling Panels 'R' 1.61
User Defined
Floor Types:
Insulated with R 5.4
Concrete Slab on Grade with 8" Block Wall
Concrete Slab on Grade with 4" Block Wall
Steel-Checker Plate with Metal Stud Wall
User Defined