TESH series resistance constant Watt heat tracing is used where circuit lengths exceed the limitations of parallel resistance heat tracing. TESH withstands the temperature exposures associated with steam purging. Thermon’s MIQ mineral insulated cables are manufactured using Alloy 825, a high nickel/chromium alloy ideally suited for high temperature service that offers exceptional resistance to stress corrosion in chloride, acid, salt and alkaline environments.
The series circuitry of TESH provides consistent
Watt-per-metre power output along the entire
length of the heat tracing with no voltage drop. A
glassceramic tape layer adds additional protection
to TESH, and a fluoropolymer overjacket provides
chemical resistance while maintaining maximum
flexibility. The construction of TES
TESH is approved for use in ordinary (nonclassified)
areas and Categories 2 and 3 ATEX classified areas.
Para obter informações sobre instalação, especificações e informações detalhadas, faça o download dos PDFs abaixo ou Encontre um representante. Se o senhor estiver pronto para adquirir esse produto para sua organização, solicite uma cotação preenchendo o formulário abaixo.